{"id":142449,"date":"2024-04-03T15:23:46","date_gmt":"2024-04-03T19:53:46","guid":{"rendered":"https:\/\/inspenet.com\/?p=142449"},"modified":"2024-06-06T15:14:41","modified_gmt":"2024-06-06T19:44:41","slug":"myths-transformation-imaging-processes","status":"publish","type":"noticias","link":"https:\/\/inspenet.com\/en\/news\/myths-transformation-imaging-processes\/","title":{"rendered":"Demystifying myths in the path of digital transformation of imaging processes"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">By Brian S. White. Textual note taken from Carestream NDT dated April 3, 2024<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Introduction &#8211; Radiography as science and craftmanship<\/h2>\n\n\n\n<p>Obtaining adequate radiographic image quality is the result of the science principles that sustain the radiographic imaging process and also of the craftmanship and experience that the radiographer puts into function while defining radiographic technique (See Figure 1-a).<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"684\" height=\"331\" src=\"https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes.webp\" alt=\"Demystifying myths in the path of digital transformation of imaging processes\" class=\"wp-image-142450\" srcset=\"https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes.webp 684w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-300x145.webp 300w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-624x302.webp 624w\" sizes=\"auto, (max-width: 684px) 100vw, 684px\" \/><figcaption class=\"wp-element-caption\">Figure 1.- Factors that affect radiographic image quality.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"788\" height=\"947\" src=\"https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-2.webp\" alt=\"Demystifying myths in the path of digital transformation of imaging processes\" class=\"wp-image-142454\" style=\"width:840px;height:auto\" srcset=\"https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-2.webp 788w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-2-250x300.webp 250w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-2-768x923.webp 768w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-2-624x750.webp 624w\" sizes=\"auto, (max-width: 788px) 100vw, 788px\" \/><figcaption class=\"wp-element-caption\">Figure 1-b.- Factors that affect radiographic image quality.<\/figcaption><\/figure>\n\n\n\n<p>In the case of digital radiography (See Figure 1-b), besides the traditional factors associated with radiographic technique such as source-to-object distance or geometric unsharpness, new parameters such as averaged frames, integration time, pixel intensity or contrast-to-noise ratio (CNR) shall be considered.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Debunking the myth of one-size-fits-all Pixel Intensity<\/h2>\n\n\n\n<p>As DDA systems are becoming more prevalent in industrial radiography, some myths have materialized. One prevalent myth while selecting DDA systems is that pixel intensity determines the CNR and detectability.<\/p>\n\n\n\n<p>It is essential to understand that exposure conditions largely determine the imaging results that are obtained for a given system. New guidelines will require the establishment of a pixel intensity range to achieve acceptable contrast sensitivity. The sensitivity will depend upon the radiographic technique, material type, material thickness, DDA type, integration time and the number of averaged frames. When the same pixel intensity has been obtained, it does not guarantee that the same contrast sensitivity has been achieved. To show this, we conducted an illustrative procedure using a Carestream NDT HPX-DR 3543 DDA, 139 mm image resolution, 139 mm pixel pitch, 14 x 17\u201d active area DDA with both X-rays (see Figure 2) and gamma rays.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"514\" src=\"https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-3-1024x514.webp\" alt=\"Demystifying myths in the path of digital transformation of imaging processes\" class=\"wp-image-142464\" srcset=\"https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-3-1024x514.webp 1024w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-3-300x151.webp 300w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-3-768x386.webp 768w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-3-1536x771.webp 1536w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-3-624x313.webp 624w, https:\/\/cdn.inspenet.com\/Demystifying-myths-in-the-path-of-digital-transformation-of-imaging-processes-3.webp 1922w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Figure 2: &#8211; Comparison of Averaged Frames for the HPX-DR 3543 DDA\nIt presents a visual comparison of averaged frames for X-ray. The image on the left was at 1 frame, 8 seconds integration time, pixel intensity of 11229, 5 wire visible, contrast-to-noise ratio CNR of 8.35. The image on the right was at 100 frames, 8 seconds integration time, pixel intensity of 11296, 1 wire visible, contrast-to-noise ratio CNR of 40.75. \nfrom Brian S. White Presentation at ASNT 2020: The Annual Conference November 9-12 \u201cExposure Guidance and the Myth of Pixel Value Dependence for Digital Detector Array Radiography.\u201d<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>In this example, even though the pixel intensities were virtually the same, the image quality for the image on the right is significantly better. This set of images speaks for itself, debunking this myth.<\/p>\n\n\n\n<p>For readers interested in exploring how digital radiography (DR) can be integrated to processes: <a href=\"https:\/\/www.carestream.com\/\" target=\"_blank\" rel=\"noopener\">https:\/\/www.carestream.com<\/a><\/p>\n\n\n\n<p>Here are some supplementary information resources from Carestream NDT\u2019s products and services portfolio:<\/p>\n\n\n\n<p>Products:<br><a href=\"https:\/\/www.carestream.com\/en\/us\/nondestructive-testing-ndt-solutions\/hpx-dr-non-glass-dr-detector\" target=\"_blank\" rel=\"noopener\">HPX-DR 3543 PE Non-Glass, Large Format Detector<\/a>,<br>HPX-DR 4336 GH High-Resolution, Large Format Detector,<br>HPX-DR 2530 PH High-Resolution, Compact Detector,<br>HPX-DR 2530 GC High-Speed, Compact Detector,<br><a href=\"https:\/\/www.carestream.com\/en\/us\/nondestructive-testing-ndt-solutions\/carestream-industrex-digital-viewing-software\" target=\"_blank\" rel=\"noopener\">INDUSTREX Digital Viewing Software<\/a>,<br>Training:\u00a0<br><a href=\"https:\/\/www.carestream.com\/en\/us\/nondestructive-testing-ndt-solutions\/ndt-classroom-trainings\" target=\"_blank\" rel=\"noopener\">Advanced Industrial Radiographic Training Academy<\/a><\/p>\n\n\n\n<p>An expanded version of this article may be found at : <a href=\"https:\/\/www.carestream.com\/en\/us\/-\/media\/publicsitev2\/resources\/ndt\/white-papers\/whitepaper_ndt_digitaltransformation_7400-900_202202_ltr_en_lores.pdf?display=inline&amp;sc_lang=en\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.carestream.com\/<\/a><\/p>\n\n\n\n<p>References:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>ASNT, <em>Nondestructive Testing Handbook, Vol. 3<\/em>: <em>Radiographic Testing<\/em>, fourth edition, Chapters 9 and 11, Columbus, OH, American Society of Nondestructive Testing.<\/li>\n\n\n\n<li>White, B., Article \u201cExposure Guidance and the Myth of Pixel Value Dependence for Digital Detector Array Radiography\u201dASNT Annual Conference, Virtual, 2020.<\/li>\n<\/ol>\n\n\n\n<p><strong>Don\u2019t miss any of our posts and follow us on social media!<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/inspenet.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">Inspenet.com<\/a>&nbsp;<a href=\"https:\/\/www.youtube.com\/@inspenet\" target=\"_blank\" rel=\"noreferrer noopener\">YouTube<\/a>&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/inspenetnetwork\" target=\"_blank\" rel=\"noreferrer noopener\">LinkedIn<\/a>&nbsp;<a href=\"https:\/\/www.facebook.com\/inspenetnetwork\" target=\"_blank\" rel=\"noreferrer noopener\">Facebook<\/a>&nbsp;<a href=\"https:\/\/www.instagram.com\/inspenet\/\" target=\"_blank\" rel=\"noreferrer noopener\">Instagram<\/a><\/p>\n\n\n\n<p>Source:&nbsp;<a href=\"http:\/\/www.carestream.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">www.carestream.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>It is essential to understand that exposure conditions largely determine the imaging results that are obtained for a given system.<\/p>\n","protected":false},"author":8403,"featured_media":142473,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"_acf_changed":false,"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categoria_noticias":[13028,13052],"etiqueta_noticias":[],"class_list":["post-142449","noticias","type-noticias","status-publish","has-post-thumbnail","hentry","categoria_noticias-mechanical-integrity","categoria_noticias-ndt"],"acf":[],"_links":{"self":[{"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/noticias\/142449","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/noticias"}],"about":[{"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/types\/noticias"}],"author":[{"embeddable":true,"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/users\/8403"}],"replies":[{"embeddable":true,"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/comments?post=142449"}],"version-history":[{"count":0,"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/noticias\/142449\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/media\/142473"}],"wp:attachment":[{"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/media?parent=142449"}],"wp:term":[{"taxonomy":"categoria_noticias","embeddable":true,"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/categoria_noticias?post=142449"},{"taxonomy":"etiqueta_noticias","embeddable":true,"href":"https:\/\/inspenet.com\/en\/wp-json\/wp\/v2\/etiqueta_noticias?post=142449"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}