The global knowledge network for professionals in the energy and industry

DÜRR NDT improves mounting for its bendable detectors

DÜRR NDT bendable detectors with a Cordura protective cover mounted on a pipe and a laptop displaying a radiographic image.

Bendable detectors from DÜRR NDT now have new covers designed to secure and protect them during industrial inspections of pipes and curved components. The update incorporates mounting options using magnets, tension straps or rubber fasteners, aiming to simplify positioning while preserving the detector’s ability to conform to the surface being examined.

The announcement, published on November 3, concerns accessories for the D-DR 1025B NDT and D-DR 1043B NDT models. The development addresses a field requirement: keeping the detector in position during acquisition and protecting it against wear from everyday handling.

Bendable detectors incorporate different mounting options

Inspection conditions vary between components. Material, geometry and available space influence detector placement and the options for securing it.

The new covers allow users to choose between three mounting methods. According to DÜRR NDT, this variety facilitates work in hard-to-reach areas and allows mounting to be adapted to the conditions of each examination.

Flexibility serves a specific purpose: bringing the detection surface closer to the object’s contour. Official documentation specifies minimum pipe diameters of 150 mm for the D-DR 1025B NDT and 300 mm for the D-DR 1043B NDT. Therefore, bending capability must be used within the limits defined for each model.

Inspenet’s coverage of digital radiography and bendable detectors at PANNDT provides background on this technology. The current update focuses on how to mount and protect it during use.

Choosing how to secure bendable detectors is part of preparing the radiographic examination. Inspectors need to consider the component’s material, curvature and accessibility when selecting among magnets, tension straps and rubber fasteners. The selected arrangement should hold the detector in the required position while respecting the manufacturer’s bending limits. These mounting alternatives address practical differences between inspection locations, allowing users to adapt the setup to the component rather than relying on a single fastening method for every pipe or curved surface encountered in the field.

Does the new cover improve image resolution?

The announced improvement concerns mounting and protection; it is not presented as an increase in detector resolution. The manufacturer states that the accessory preserves the flexibility and imaging characteristics of both devices.

Both models have a pixel pitch of 99 µm. The technical data sheet distinguishes between scintillator configurations and specifies a maximum basic spatial resolution of 100 µm for the Fine option and 130 µm for Standard.

Their active areas also differ: 97 × 249 mm for the D-DR 1025B NDT and 97 × 427 mm for the D-DR 1043B NDT. These dimensions describe the available sensitive surface, rather than the equipment’s external dimensions.

Distinguishing these parameters avoids attributing capabilities to the accessory that belong to the detection system. Radiographic testing and its application through digital radiography help place this distinction within the preparation and evaluation of an inspection.

Cordura protects the detector during fieldwork

The covers use Cordura® fabric, selected to withstand abrasion, dirt and mechanical stresses associated with industrial use. DÜRR NDT states that this protection helps reduce wear on the detector’s surface.

The design aims to preserve portability, low weight and bending capability. For inspectors, the value lies in having protection during operation without making the assembly more difficult to handle.

The release does not quantify the increase in service life or publish comparative resistance test results. Extended service life should be understood as a benefit stated by the manufacturer, without assigning a specific additional duration.

This update complements DÜRR NDT’s track record in industrial radiography, with attention to the accessories that accompany the equipment in the field.

D-Tect X maintains integrated radiographic analysis

Both detectors operate with D-Tect X, DÜRR NDT’s inspection software. The cover supports handling and mounting; acquisition and evaluation continue within the manufacturer’s digital environment.

The solution connects a practical requirement with the inspection workflow: positioning, protecting, acquiring and analyzing. Its contribution lies in facilitating the initial stages while maintaining the detector’s characteristics and offering mounting alternatives according to the component being examined.

Sources: DÜRR NDT, press release supplied to Inspenet / Official announcement of the new covers / Technical documentation for the D-DR 1025B and D-DR 1043B NDT detectors.

Verified Author

Mechanical Engineer with more than 30 years of experience in inspection and management. Currently, he is Director of Operations at INSPENET.