Table of Contents
- What is custom PAUT software
- Applications from the lab to the production line
- Integration problems between software and equipment
- What does this mean in practice
- Standard or custom PAUT software
- Requirements for inspection automation and integration
- Standards applicable to PAUT and TFM examinations
- Software validation and examination traceability
- How TPAC approaches custom PAUT software
- Conclusion
- References
- Frequently Asked Questions (FAQs)
PAUT software supports phased array ultrasonic inspection setup, signal visualization, and storage of examination results. Some applications, however, need additional functions to coordinate scanners, process data, or communicate with production systems. In these situations, software selection should be driven by verifiable requirements for acquisition, integration, and traceability.
Within mechanical integrity programs, custom development can address these needs through application-specific functions and interfaces. Its suitability depends on the component, examination technique, hardware, and applicable procedure. Understanding these relationships helps engineers choose among standard software, an adaptation, and a custom application.
What is custom PAUT software
Custom PAUT software is an application developed or adapted for specific phased array ultrasonic inspection requirements. Its scope may include setup, acquisition, processing, and interfaces, depending on the agreed requirements and hardware capabilities. Within non destructive testing (NDT), these functions support examination execution and documentation.
Configuration versus custom development
Configuration means adjusting available settings, such as gain, range, focal laws, or acquisition increment. Custom development may involve adding functions, modifying workflows, or implementing interfaces. The distinction depends on the scope of the change; customization does not necessarily mean building an application from scratch.
For example, selecting an available sectorial scan is configuration. Programming a function that links ultrasonic records to each part’s identifier is application-specific development.
PAUT and FMC acquisition with TFM processing
PAUT stands for phased array ultrasonic testing. In conventional PAUT, transmit and receive delays allow electronic beam steering and focusing. In full matrix capture (FMC), each element transmits in sequence, and the array records the responses for the transmit-receive element pairs.
The total focusing method (TFM) reconstructs a region of interest by calculating focusing at points within that region. Acquisition and reconstruction are separate stages; their implementation depends on the system.
Applications from the lab to the production line
Software requirements vary by operating environment. A laboratory may need access to individual element signals, a field inspection may need a reliable link between position and recorded data, and a production line may need coordination with other equipment. These different needs should be reflected in the functional specification.
Laboratory work and algorithm development
In research, the data and parameters needed to reproduce processing must be retained. Comparing TFM algorithms using the same FMC dataset, for example, allows their differences to be studied without introducing variation from a new acquisition.
Field inspection with scanners
During an encoded scan, records are associated with position measured by an encoder. For a girth weld, for example, the scan origin, direction of travel, and conversion of encoder counts to distance should be verified.
Inspection integrated into production
In production, inspection must be coordinated with part identification and handling. The following examples show how these needs translate into functions.
| Environment | Inspection need | Required function |
| Laboratory | Compare reconstructions using equivalent data. | Access to signals, parameters, and processing algorithms. |
| Field | Locate indications relative to the component. | Association of ultrasonic records with encoded position. |
| Production | Associate each examination with a part. | Part identification, acquisition sequences, and exchange of results. |
Functions and operating conditions must be specified for each project.
Integration problems between software and equipment
An integration problem arises when available functions do not meet the requirements of the examination procedure or industrial process. Engineers must identify the missing operation, the information to be exchanged, and how to verify execution. Customization starts with that assessment, followed by a decision on whether software, hardware, or both need to change.
Missing functions and interfaces
A communication port alone does not establish functional compatibility. Commands, formats, units, and operating states must be checked. Connecting a scanner, for example, requires verifying how position is transmitted and how the system responds to an interruption.
Motion and acquisition out of sync
Scan speed must be compatible with the ultrasonic sequence and acquisition capacity. For example, traveling at 100 mm/s and recording every 1 mm requires 100 complete acquisition cycles per second. Each cycle may require multiple ultrasonic firings.
These values are illustrative. The allowable acquisition increment and scan speed are determined by the procedure and must be verified during scanning.
Disconnected records and manual tasks
Exporting signals, positions, and identifiers to separate files can make an examination difficult to reconstruct unless those records remain unambiguously linked. The risk increases when component names, units, or references are entered manually.
A useful integration requirement is to retain the part identifier, examination setup, and acquired records together. Reviewers can then determine which information belongs to each examination and what evidence supported the evaluation.
What does this mean in practice
Integration is evaluated across a complete inspection sequence. The following hypothetical scenario illustrates requirements an integrator might specify to maintain coverage, identification, and examination evidence.
Example of an automated inspection station
Consider a proposed station for examining welds with a motorized scanner. The specification calls for identifying the component, loading an approved setup, and associating signals with encoder positions. At completion, the file is to be checked and the examination status communicated.
If the scan is interrupted, the specification may require the system to flag the incomplete scan and support a controlled rescan or recovery. That function requires specific implementation and verification. Completing the mechanical travel alone does not demonstrate that all required data were acquired.
Rescans and delays caused by lost traceability
An incorrect link between a file and a component may require records to be reviewed or the examination to be repeated. Positions without valid data can also prevent the required coverage from being demonstrated. Methods for identifying these conditions should be defined before results are released for technical evaluation.
Standard or custom PAUT software
Selection starts by comparing procedure requirements with the documented functions of the available software. A standard application may fully meet the need. Custom development is justified when functional requirements call for adaptation and can be verified through testing.
When standard software is sufficient
Standard PAUT software is suitable when it supports the required technique setup, controls compatible accessories, records the necessary data, and generates the required results. The manufacturer’s operating conditions and limitations must also be checked.
When to adapt or develop functions
Customization is worth evaluating when an application requires additional algorithms, automated sequences, or communication through specific equipment interfaces. One example is linking the ultrasonic result to a serial number managed by the production system.
| Option | When it fits | Main limitation |
| Standard software | Available functions meet procedure and equipment requirements. | Changes are limited by the available options and interfaces. |
| Software adaptation | A compatible platform exists, but specific interfaces or tasks are missing. | The permitted scope of modification and ongoing maintenance must be established. |
| Custom development | The application requires specific acquisition, processing, or integration functions. | Specifications, validation, and support are needed throughout the software lifecycle. |
Total cost and ongoing support
The cost assessment should include licensing, engineering, testing, training, and updates. It should also establish who will maintain interfaces and how compatibility will be verified when the instrument, operating system, or connected equipment changes.
Requirements for inspection automation and integration
The functional specification should define inputs, operations, outputs, and failure conditions. The checks below help the integrator and technical lead agree on functional acceptance criteria.
The article on phased array ultrasound and open NDT platforms provides additional context on system architecture.

SDKs and APIs for control and data exchange
An application programming interface (API) defines how software accesses particular functions or data. A software development kit (SDK) may include libraries, documentation, and examples for implementing those connections. Availability must be checked against the functions the manufacturer actually exposes.
Synchronization and processing capacity
Scan speed, firing sequence, and data volume affect acquisition. PAUT software performance must be verified together with the instrument, communications, processing, and storage under the intended operating conditions.
The article on high-speed data acquisition for ultrasonic NDT provides additional guidance on data throughput and bottleneck analysis.
| Requirement | What to define | How to verify it |
| Position and acquisition | Acquisition increment, scan origin, and direction of travel. | Use a known travel distance and review records by position. |
| Acquisition capacity | Ultrasonic sequence and operating speed. | Run a representative scan and check for missing data. |
| External communications | Commands, states, and interruption handling. | Test data exchange, disconnection, and recovery. |
| Traceability | Component identification and examination setup. | Retrieve and review the examination record. |
| Storage | Data, metadata, and retention conditions. | Open, read, and compare saved files. |
File formats and external communications
Files must retain enough information to interpret the examination, including the component, setup, coordinates, and relevant results. Export functions should be checked for loss of units, reference information, or data needed for review.
Standards applicable to PAUT and TFM examinations
The choice of standards depends on the component, material, technique, and contract. The following references help guide that choice; they do not constitute software certifications. Software functions are evaluated within the applicable examination system and procedure.
ISO references for PAUT and FMC/TFM
These standards cover different applications. Minimum thickness alone does not determine applicability. Material, geometry, and examination conditions must also be checked.
| Standard | Application | Scope and limitations |
| ISO 13588:2019 | Semi- or fully automated PAUT of welds. | Full-penetration welds of simple geometry in low-alloy and/or fine-grained steels; minimum thickness 6 mm. Does not establish acceptance levels. |
| ISO 23865:2021 | General application of FMC/TFM. | General provisions for materials within its scope, subject to homogeneity and isotropy conditions. Does not establish acceptance levels. |
| ISO 23864:2021 | Semi- or fully automated TFM examination of welds. | Full-penetration welds of simple geometry; minimum thickness 3.2 mm and specific material conditions. Does not establish acceptance levels. |
| ISO 19285:2017 | Acceptance levels for welds examined using PAUT. | Full-penetration welds in ferritic steels; minimum thickness 6 mm. Applies to indications classified in accordance with ISO 13588. |
The table summarizes the official scope descriptions. Applying these standards requires consulting the complete documents. Each project must identify the examination reference, acceptance criteria, and contractually required edition, including applicable amendments.
Codes and acceptance criteria
ASME BPVC Section V contains examination requirements when invoked by the governing code. Acceptance is determined using the applicable reference.
API Standard 1104, issued by the American Petroleum Institute, addresses pipeline welding and inspection within its scope. Here, API identifies the standards organization; in software development, it means application programming interface.
SNT-TC-1A is a recommended practice for NDT personnel qualification and certification; ANSI/ASNT CP-189 is a standard for that purpose. Neither certifies software. The required scheme determines the employer’s written practice or certification procedure.
Software validation and examination traceability
To evaluate the intended use of PAUT software, each functional requirement should be linked to tests, expected results, and retained evidence. The following criteria are general engineering recommendations. The validation plan must incorporate any procedure qualification or demonstration requirements applicable to the project.
Functional tests and reference results
The test plan may cover setup, acquisition, position association, processing, storage, and retrieval. Reference blocks and controlled datasets allow comparison against known responses.

Reprocessing files verifies certain software functions, but does not by itself demonstrate the performance of the complete inspection chain. For applications that include automated detection, the article on NDT algorithm validation discusses representative data and detection errors.
For example, after changing a reconstruction algorithm, it is useful to process a known FMC dataset and compare reflector position, amplitude, and image representation. Tolerances should be defined before the change is accepted, based on the application and procedure. Tests using representative components or blocks must also check sensitivity, calibration, and acoustic coupling, as required by the procedure. Correct synchronization alone does not guarantee the required detection capability.
Version control and change management
Traceability is supported by identifying the relevant software versions and examination setup. An update that changes calculations, coordinates, or exports requires an impact assessment and appropriate regression testing under the applicable change control process.
Depending on application risk, testing may include encoder disconnection, communication interruptions, or insufficient storage space. The expected response to each failure must be agreed on and verified; it should not be assumed to be available in every product.
How TPAC approaches custom PAUT software
According to its official website, TPAC, The Phased Array Company, offers custom ultrasonic software development under its Custom Software service. The company describes laboratory applications, field interfaces with scanners, and inline software connected to production tools.
The term “custom PAUT software” describes this article’s focus. TPAC’s Custom Software service covers a broader range of ultrasonic applications.
From technical requirements to a solution
TPAC states that it analyzes customer needs and helps prepare a software requirements specification. Its offering includes setup, acquisition, and analysis applications, as well as interfaces between devices and existing software.
In a hypothetical project, an integrator might request part identification and association of signals with coordinates. TPAC would need to assess feasibility and scope.
Tools for acquisition and integration
The Custom Software documentation lists tools for hardware control, phased array, TFM processing, input/output management across multiple protocols, and data extraction through an open file format. Compatibility, performance, and deliverable file formats must be confirmed for the project.
In its Pioneer specifications, TPAC identifies an SDK with example source code, a high-level API for FMC/TFM techniques, and a TFM library. These features apply to that platform and should not be generalized to the entire product portfolio.
TPAC interview on Inspenet TV
The published summary of the TPAC interview on Inspenet TV, featuring Alan Caulder at API Summit 2026, presents the company’s approach to open platforms and software-based adaptation. Functions and compatibility must be confirmed through technical documentation and the scope agreed on with TPAC.
To evaluate a specific ultrasonic integration project, contact TPAC through Inspenet and outline your acquisition, processing, and communication requirements.
Conclusion
Custom PAUT software adds value when it meets inspection requirements that standard software does not cover. Evaluation should consider acquisition, processing, synchronization, data exchange, and retention of evidence, together with the project’s applicable standards and code requirements. The decision requires comparing alternatives, verifying functions, and agreeing on maintenance and change control. TPAC’s Custom Software service can be evaluated within that process. Examination compliance depends on the procedure, equipment, personnel, and applicable acceptance criteria.
Discuss your application with TPAC
Before discussing a solution, assemble the essential requirements: component, material, ultrasonic technique, scan speed, spatial resolution, data to be retained, and equipment to be integrated. This information supports a discussion of development scope and acceptance testing. Contact TPAC through Inspenet to present your application requirements.
References
- International Organization for Standardization (ISO). (2021). ISO 23865:2021. Non-destructive testing, Ultrasonic testing, General use of full matrix capture/total focusing technique (FMC/TFM) and related technologies. Official catalog entry and scope summary.
- Zavarce, A. (2026, May 8). Phased array ultrasound and open platforms in NDT. Inspenet. Further reading.
- Quiñonez, E. (2026, September 3). High-speed data acquisition in ultrasonic NDT with OEM electronics. Inspenet. Further reading.
- International Organization for Standardization (ISO). (2019). ISO 13588:2019. Non-destructive testing of welds, Ultrasonic testing, Use of automated phased array technology. Official catalog entry and scope summary.
- International Organization for Standardization (ISO). (2021). ISO 23864:2021. Non-destructive testing of welds, Ultrasonic testing, Use of automated total focusing technique (TFM), and related technologies. Official catalog entry and scope summary.
- International Organization for Standardization (ISO). (2017). ISO 19285:2017. Non-destructive testing of welds, Phased array ultrasonic testing (PAUT), Acceptance levels. Official catalog entry and scope summary.
- American Society of Mechanical Engineers (ASME). (2025). BPVC-V-2025. Section V, Nondestructive Examination. ASME publisher description on ANSI Webstore. Use the edition required by the project.
- American Petroleum Institute (API). (n.d.). API Standard 1104: 22nd Edition. Official announcement concerning Welding of Pipelines and Related Facilities. Use the edition and amendments required by the project.
- American Society for Nondestructive Testing (ASNT). (n.d.). Employer-Based Certification Accreditation Program. Official information on programs based on SNT-TC-1A and ANSI/ASNT CP-189.
- Rodríguez, M. (2026, October 27). NDT algorithm validation: What to verify before trusting the results. Inspenet. Further reading.
- TPAC, The Phased Array Company. (n.d.). Custom Software. Official service description.
- TPAC, The Phased Array Company. (n.d.). Pioneer. Official platform description and specifications.
- Inspenet TV. (2026, August 7). TPAC redefines industrial inspection with open platforms. Published summary of the interview with Alan Caulder at API Summit 2026.
Frequently Asked Questions (FAQs)
What is custom PAUT software?
It is an application developed or adapted to meet specific phased array ultrasonic inspection requirements. Its scope may include acquisition, processing, visualization, control, and data exchange, depending on the agreed requirements and hardware capabilities.
Is configuration the same as customization?
Configuration adjusts existing settings, such as gain, range, or focal laws. Customization changes or adds capabilities. An example is developing an interface that links ultrasonic records to part identifiers supplied by the production system.
What is the difference between an SDK and an API?
An API defines mechanisms for accessing functions or exchanging data. An SDK provides development resources that may include libraries, documentation, and examples. The available operations and compatibility with the instrument and computing environment must be verified.
Can it be integrated with robots and scanners?
Integration is possible when compatible interfaces and a suitable architecture can coordinate acquisition and motion. Positions, states, sequences, and fault responses should be checked. Feasibility depends on the equipment, interfaces, and functions the supplier confirms for the project.
Which standards should be considered?
This depends on the component, material, technique, and contract. Relevant references may include ISO standards for PAUT and FMC/TFM, ASME or API requirements, and personnel qualification documents. Examination requirements must be distinguished from acceptance criteria, and the specified editions must be used.
How is custom software validated?
Validation uses tests linked to requirements and intended use. These may cover functions, known reference responses, files, interfaces, and failures. The scope is defined for each application. Software validation does not replace inspection system checks or procedure qualification or demonstration when required.