The global knowledge network for professionals in the energy and industry

Improving ultrasonic thickness measurement in complex geometries with adaptive imaging and double profilometry

Learn how adaptive ultrasonic imaging and double profilometry improve thickness measurement accuracy in complex geometries, corroded assets, and noisy inspection environments.
Improving ultrasonic thickness measurement in complex geometries with adaptive imaging and double profilometry

Why conventional ultrasonic thickness measurement falls short on complex geometries?

Conventional ultrasonic techniques are widely used in nondestructive testing (NDT): for corrosion monitoring, remaining life assessment, and asset integrity management. In industries such as oil & gas, power generation, and petrochemicals, inspectors rely on ultrasonic testing (UT) to determine wall thickness and identify material loss caused by corrosion. These techniques work well for simple geometries where the linear scan is reliable. However, conventional ultrasonic techniques for thickness measurement are based on gated echoes and vertical propagation assumptions [1]. Thickness is calculated from the time-of-flight between the front-wall and back-wall echoes, assuming that ultrasonic waves travel perpendicular to the surface and return along the same path.

When inspecting components with curved surfaces, irregular geometries, corrosion damage, or complex profiles, wave propagation is no longer purely vertical. Refraction, and scattering phenomena can significantly affect echo positioning, leading to inaccurate measurements.

These challenges are common when monitoring corrosion of pipes, elbows, nozzles, welded transitions, and other complex assets found throughout oil & gas facilities. In such areas, conventional ultrasonic thickness measurements may underestimate or overestimate the true remaining wall thickness due to non-vertical wave propagation and complex echo behavior. This can reduce confidence in integrity assessments and make it more difficult to accurately evaluate corrosion damage or remaining service life.

 FIGURE 1. Schematic representation of ultrasonic wall thickness (WT) measurement using A-scan gating. In simple geometries, the measured ultrasonic path corresponds closely to true thickness. In complex geometries, non-vertical wave propagation and diffraction effects introduce ambiguity in echo interpretation, reducing measurement reliability.
FIGURE 1. Schematic representation of ultrasonic wall thickness (WT) measurement using A-scan gating. In simple geometries, the measured ultrasonic path corresponds closely to true thickness. In complex geometries, non-vertical wave propagation and diffraction effects introduce ambiguity in echo interpretation, reducing measurement reliability.

Source – Illustration courtesy of Nans Laroche, TPAC

Moving beyond conventional gated measurements with adaptive imaging and double profilometry

To address these limitations, we introduce an adaptive ultrasonic imaging approach combined with double profilometry, designed to deliver robust and accurate thickness mapping even under adverse conditions.  Unlike conventional thickness measurements performed directly on individual A-scans, the proposed approach first reconstructs an ultrasonic image from a large set of ultrasonic signals. By coherently combining information from multiple transmit-receive paths, the ultrasonic image provides enhanced signal-to-noise ratio and spatial localization. More importantly, the adaptive imaging process explicitly accounts for the complex entry-surface geometry and the associated refraction effects during image reconstruction, providing a more reliable basis for thickness measurement.

The external surface is used to adapt to the reconstruction process, while the internal surface is estimated directly from the resulting image. Thickness measurements are then obtained from the distance between the external and internal surfaces, a process referred to as double profilometry. 

This allows thickness to be determined globally across the geometry rather than locally along isolated ultrasonic propagation paths.

Caption FIGURE 2 Workflow for external profilometry. Raw FMC data are acquired on a component with a complex surface geometry. A preliminary TFM image is reconstructed assuming propagation in a homogeneous water medium, allowing the external surface echo to be localized and modeled prior to adaptive ultrasonic imaging.
FIGURE 2. Workflow for external profilometry. Raw FMC data are acquired on a component with a complex surface geometry. A preliminary TFM image is reconstructed assuming propagation in a homogeneous water medium, allowing the external surface echo to be localized and modeled prior to adaptive ultrasonic imaging.

Source – Illustration courtesy of Nans Laroche, TPAC

Improved reliability for corrosion monitoring

Testing performed on industrial components demonstrated that double profilometry can successfully track internal surfaces even when back-wall responses are weak.

Unlike traditional gated techniques, the approach provides a continuous thickness map while simultaneously generating internal and external surface information.

The implementation is optimized for high-speed inspection and can produce several hundred reconstructed images and double-profilometry-based thickness measurements per second in both FMC and PWI acquisition modes.

For asset owners and inspection service providers, this means faster inspections, improved reliability, and more dependable thickness measurements in situations where conventional UT methods may produce incomplete or inaccurate results.

FIGURE 3  Welded fin tube inspection performed directly on the weld, detecting wall thinning. The minimum measured thickness is 1.22 mm at the thinnest point, compared to 2.0 mm in the non-welded section of the tube.
FIGURE 3.  Welded fin tube inspection performed directly on the weld, detecting wall thinning. The minimum measured thickness is 1.22 mm at the thinnest point, compared to 2.0 mm in the non-welded section of the tube.

Source –  courtesy of Nans Laroche, TPAC

Looking ahead

As industrial components become increasingly complex and inspection requirements continue to evolve, adaptive imaging is emerging as a powerful extension of conventional ultrasonic thickness measurement.

Future developments will focus on multimode adaptive imaging approaches that combine refraction and reflection modeling to further improve defect characterization in complex geometries.

FIGURE 4. Adaptive Total Focusing Method with external and internal profilometry for thickness measurement on a thin welded tube with complex geometry. The algorithm successfully tracks the internal profile and performs reliable thickness measurements even in regions where the backwall echo exhibits very low contrast.
FIGURE 4. Adaptive Total Focusing Method with external and internal profilometry for thickness measurement on a thin welded tube with complex geometry. The algorithm successfully tracks the internal profile and performs reliable thickness measurements even in regions where the backwall echo exhibits very low contrast.

Source – courtesy of Nans Laroche, TPAC

By combining adaptive ultrasonic imaging, FMC, PWI, and double profilometry, inspectors can achieve reliable thickness measurements even in areas where conventional gated methods become unreliable. The result is improved corrosion assessment, better geometry reconstruction, and greater confidence in integrity management decisions.

Equipment and setup

The results shown in Figure 4 were obtained using a TPAC Explorer Max 64/128 phased array instrument, paired with a high frequency probe. Data were acquired and processed using the Adaptive TFM technique in Prelude software. The test piece was a welded tube; its complex geometry makes conventional gated thickness measurement challenging.

1 IMG 5 ESP Mejora de la medicion ultrasonica del espesor en geometrias complejas mediante imagenes adaptativas y profilometria doble.png resultado copia

References

[1] ISO 16809:2025 – non-destructive testing — Ultrasonic thickness determination, ISO 16809:2025, Geneva, Switzerland., 2025.

Written by
Verified Author

Is an R&D Engineer at TPAC, where he develops advanced ultrasonic inspection technologies for complex geometries and demanding industrial applications. His areas of expertise include acquisition and imaging techniques, including adaptive imaging, Full Matrix Capture (FMC), Total Focusing Method (TFM), and high-speed ultrasonic data processing. 

Verified Author

Is a Marketing Manager at TPAC. She specializes in technical marketing for advanced UT nondestructive testing (NDT) technologies. Working closely with TPAC’s engineering and R&D teams, she helps translate complex ultrasonic inspection concepts into accessible content for industry professionals, supporting knowledge sharing and technology adoption across the NDT community.