Why conventional ultrasonic thickness measurement falls short on complex geometries?
Conventional ultrasonic techniques are widely used in nondestructive testing (NDT): for corrosion monitoring, remaining life assessment, and asset integrity management. In industries such as oil & gas, power generation, and petrochemicals, inspectors rely on ultrasonic testing (UT) to determine wall thickness and identify material loss caused by corrosion. These techniques work well for simple geometries where the linear scan is reliable. However, conventional ultrasonic techniques for thickness measurement are based on gated echoes and vertical propagation assumptions [1]. Thickness is calculated from the time-of-flight between the front-wall and back-wall echoes, assuming that ultrasonic waves travel perpendicular to the surface and return along the same path.
When inspecting components with curved surfaces, irregular geometries, corrosion damage, or complex profiles, wave propagation is no longer purely vertical. Refraction, and scattering phenomena can significantly affect echo positioning, leading to inaccurate measurements.
These challenges are common when monitoring corrosion of pipes, elbows, nozzles, welded transitions, and other complex assets found throughout oil & gas facilities. In such areas, conventional ultrasonic thickness measurements may underestimate or overestimate the true remaining wall thickness due to non-vertical wave propagation and complex echo behavior. This can reduce confidence in integrity assessments and make it more difficult to accurately evaluate corrosion damage or remaining service life.

Source – Illustration courtesy of Nans Laroche, TPAC
Moving beyond conventional gated measurements with adaptive imaging and double profilometry
To address these limitations, we introduce an adaptive ultrasonic imaging approach combined with double profilometry, designed to deliver robust and accurate thickness mapping even under adverse conditions. Unlike conventional thickness measurements performed directly on individual A-scans, the proposed approach first reconstructs an ultrasonic image from a large set of ultrasonic signals. By coherently combining information from multiple transmit-receive paths, the ultrasonic image provides enhanced signal-to-noise ratio and spatial localization. More importantly, the adaptive imaging process explicitly accounts for the complex entry-surface geometry and the associated refraction effects during image reconstruction, providing a more reliable basis for thickness measurement.
The external surface is used to adapt to the reconstruction process, while the internal surface is estimated directly from the resulting image. Thickness measurements are then obtained from the distance between the external and internal surfaces, a process referred to as double profilometry.
This allows thickness to be determined globally across the geometry rather than locally along isolated ultrasonic propagation paths.

Source – Illustration courtesy of Nans Laroche, TPAC
Improved reliability for corrosion monitoring
Testing performed on industrial components demonstrated that double profilometry can successfully track internal surfaces even when back-wall responses are weak.
Unlike traditional gated techniques, the approach provides a continuous thickness map while simultaneously generating internal and external surface information.
The implementation is optimized for high-speed inspection and can produce several hundred reconstructed images and double-profilometry-based thickness measurements per second in both FMC and PWI acquisition modes.
For asset owners and inspection service providers, this means faster inspections, improved reliability, and more dependable thickness measurements in situations where conventional UT methods may produce incomplete or inaccurate results.

Source – courtesy of Nans Laroche, TPAC
Looking ahead
As industrial components become increasingly complex and inspection requirements continue to evolve, adaptive imaging is emerging as a powerful extension of conventional ultrasonic thickness measurement.
Future developments will focus on multimode adaptive imaging approaches that combine refraction and reflection modeling to further improve defect characterization in complex geometries.

Source – courtesy of Nans Laroche, TPAC
By combining adaptive ultrasonic imaging, FMC, PWI, and double profilometry, inspectors can achieve reliable thickness measurements even in areas where conventional gated methods become unreliable. The result is improved corrosion assessment, better geometry reconstruction, and greater confidence in integrity management decisions.
Equipment and setup
The results shown in Figure 4 were obtained using a TPAC Explorer Max 64/128 phased array instrument, paired with a high frequency probe. Data were acquired and processed using the Adaptive TFM technique in Prelude software. The test piece was a welded tube; its complex geometry makes conventional gated thickness measurement challenging.

References
[1] ISO 16809:2025 – non-destructive testing — Ultrasonic thickness determination, ISO 16809:2025, Geneva, Switzerland., 2025.