In industrial radiography, the price of film represents only part of the overall cost. Film processing, chemicals, waiting time, retakes, transportation, and archiving consume resources before an inspection decision can be made. Therefore, the transition to digital radiography should be evaluated based on the total cost of the workflow, from exposure through final reporting.
The transition becomes more advantageous when computed radiography (CR) or digital radiography (DR) eliminates processing steps without compromising image quality or code compliance. The primary objective is to identify where digital radiography for NDT reduces the cost per acceptable radiograph and allows inspections to be completed with fewer delays, without forcing the replacement of film in applications where it remains the better option.
The cost of NDT film beyond exposure
A film-based radiography workflow incurs costs before and after exposure, including inventory, cassettes, processing chemicals, development, drying, viewing, archiving, and waste disposal. When image interpretation takes place away from the inspected asset, a delay arises between capturing the radiograph and determining whether it is acceptable.
That delay can lead to rework. A rejected radiograph may require recreating the exposure geometry, repositioning the radiation source, or returning to the inspection location. During a plant shutdown or remote field inspection, crew hours and mobilization costs can exceed the cost of the film itself.
An economic assessment of the transition to DR considers film costs, chemicals, inventory, waste disposal, scanning, archiving, and retakes. Carestream NDT’s technical documentation addresses these factors and associates immediate image availability with increased productivity. These considerations help determine whether switching to digital radiography is economically justified for a particular application.
The digitalization of NDT inspections turns these scattered expenses into measurable variables: time to interpretation, retake rate, labor hours, travel, consumables, and storage. The question is no longer simply how much film costs, but how much it costs to produce a technically acceptable radiograph.
What the business case must demonstrate
Two operations with similar film consumption may have very different costs. One processes radiographs near the inspected asset, while another depends on transportation, a darkroom, or a remote processing station. For this reason, return on investment should not be projected using a generic figure.
The assessment should distinguish four cost categories:
- Consumables: Radiographic film, processing chemicals, cassettes, imaging plates, and replacements.
- Processing: Film development or image scanning, setup, image review, and retakes.
- Logistics: Transportation, return visits to the inspection location, inventory, and physical archiving.
- Information management: Digitization, retrieval of historical records, image transfer, and storage.
Computed radiography may be sufficient when inspection geometry requires flexible imaging plates and scanning time is not a major cost driver. Direct digital radiography becomes more attractive when immediate image availability eliminates delays, retakes, or unnecessary travel.
A well-supported transition to digital radiography compares the total cost per acceptable radiograph. If an application does not demonstrate measurable technical or operational improvements, retaining film or CR may remain a valid decision.
Selecting CR and DR based on the application
Computed radiography uses photostimulable phosphor imaging plates that must be scanned after exposure. This eliminates chemical film processing and produces a digital image, but an additional step remains between image capture and interpretation.
Direct digital radiography uses digital detector arrays (DDAs) to provide images almost immediately. This allows inspectors to verify positioning, identification markers, image quality indicators (IQIs), and overall image quality before dismantling the exposure setup, provided the detector and examination procedure are suitable for the application.
Geometry remains a determining factor. Rigid detectors can limit certain inspection configurations, while CR imaging plates offer greater flexibility. Carestream expanded the possibilities of DR with the INDUSTREX HPX-ARC 1025 PH and 1043 PH, bendable detectors featuring a 98 µm pixel pitch. These detectors can be used in a flat configuration or bent to minimum diameters of 2 inches and 4 inches, respectively.
The transition does not require eliminating film from every application. Industrial radiographic film, CR, and DR remain available because each modality addresses different technical and operational requirements. Switching to digital radiography makes the most sense when decisions are made application by application, comparing geometry, required image quality, productivity, and total workflow costs before replacing a technology that still meets inspection requirements.
Digital radiography for NDT does not require a single technology across every inspection. CR may be appropriate when geometric flexibility and examination setup are the main considerations, while DR may offer greater value when faster image availability, immediate verification, and higher daily inspection throughput produce a stronger return on investment.
The following video demonstrates how bendable DR detectors and field image review tools can reduce repositioning, accelerate image validation, and expand inspection capabilities for curved components.
Industrial radiography software for avoiding hidden costs
A phased transition may reduce film consumption while introducing new expenses if CR and DR operate through separate software platforms, interpretation workstations, configurations, and image archives. Investment decisions must also account for what happens after image acquisition: interpretation, transfer, storage, and record management.
Maintaining separate workflows can increase training, administration, and configuration requirements while introducing inconsistencies in image viewing practices. It may also make consistent traceability more difficult when both modalities operate within the same inspection program.
A common software platform can reduce this fragmentation. INDUSTREX Digital Viewing Software Version 7.3 supports both CR and DR, integrating image acquisition, viewing, analysis, storage, and image management. Its DICONDE compatibility helps preserve radiographic information in a consistent data structure.

Saving time must not compromise radiographic quality control
In nondestructive testing (NDT), reducing inspection time provides little value if the resulting image fails to meet the examination procedure. ASTM E2445/E2445M-20 establishes performance evaluation and long-term stability testing requirements for CR systems, while ASTM E2737-23 addresses the performance evaluation and long-term stability of digital detector arrays throughout their service life.
In DR, basic spatial resolution, signal-to-noise ratio, contrast sensitivity, image lag, and detector corrections affect image quality. In CR, relevant factors include the imaging plate, scanner, scanning parameters, and overall system stability. Digital radiography for NDT requires control of the complete imaging system.
ASME BPVC Section V, 2025 Edition, establishes nondestructive examination requirements when invoked by the applicable code. The digitalization of NDT inspections must be incorporated into documented examination procedures, personnel qualification requirements, and quality control practices, while acceptance criteria remain governed by the applicable construction or in-service inspection code or specification.
This establishes a fundamental limit: switching to digital radiography creates value only when productivity improvements and code compliance are achieved together. Cost savings should be calculated only after demonstrating that the resulting radiographs meet the applicable technical requirements.
A field case demonstrates the cost of waiting for results
A field application documented by Carestream NDT illustrates how computed radiography can eliminate operational steps during remote inspections. Kakivik Asset Management used the INDUSTREX HPX-PRO system to inspect welds on a natural gas pipeline in Alaska.
According to Carestream NDT’s published Kakivik Asset Management testimonial, similar work performed with film required returning to Anchorage to process and evaluate radiographs. With the HPX-PRO system, the crew was able to expose, process, interpret, and complete the inspection on-site. Kakivik reported a 30% improvement in efficiency and a 50% reduction in exposure times during its experience with the system.
These results are specific to the company’s reported experience and should not be interpreted as universal cost savings. What can be applied to other operations is the measurement approach: avoided trips, crew hours, time to results, retakes, and the ability to complete an inspection before dismantling the setup.
The same operational principle applies to current DR tools. INDUSTREX Fieldview enables inspectors to review image quality at the inspection location and determine whether a retake is necessary before leaving the area. The tool supports field verification of image acquisition, identification markers, and IQIs, reducing the risk of discovering an unacceptable radiograph after the crew has moved on.
From pilot testing to a defensible digital transition
Switching to digital radiography should begin with applications where current inspection costs can be measured reliably. A selected group of welds, a production line, or a field inspection service provides an opportunity to compare film, CR, and DR without immediately changing the entire operation.
The pilot should record setup time, exposure time, processing time, interpretation time, retake percentage, labor hours, consumables, and time to final reporting. Image quality and compliance with applicable requirements must also be documented to ensure that increased productivity does not conceal technical deficiencies.
At this stage, computed radiography, direct digital radiography, and industrial radiography software should be evaluated as a single workflow. Image acquisition, review, transfer, and archiving must remain consistent across different modalities and inspection configurations.
Effective digitalization of NDT inspections relies on data collected from actual operations to determine where each modality delivers value. This approach makes it possible to present the investment to inspection teams, operations management, and financial decision-makers using verifiable results rather than general claims.
What Is the real cost of maintaining a Film-aased Workflow?
When processing, retakes, transportation, or waiting times increase the cost of radiographic inspection, a technical evaluation with Carestream NDT can help identify which applications justify the transition to CR or DR and which operational improvements can be measured before making an investment.
Conclusions
The true cost of film becomes clearer when the entire inspection workflow is considered, from exposure to final reporting. Switching to digital radiography can reduce expenses associated with processing, waiting times, retakes, transportation, and archiving, provided the selected application can maintain the required radiographic image quality.
CR and DR offer different advantages depending on inspection geometry, operating conditions, and image availability. A common software platform can facilitate the transition, but decisions must be supported by verifiable results. Comparing image quality, compliance, and cost per acceptable radiograph provides a sound basis for justifying investment without compromising technical control.
References
- ASTM International. ASTM E2445/E2445M-20 and ASTM E2737-23.
- ASME. BPVC Section V, Nondestructive Examination, 2025.
- Carestream NDT. INDUSTREX Digital Viewing Software Version 7.3, 2026.
- Carestream NDT. Building Your Own Use Case for a Conformable DR Detector, Parts I–III, 2025.
- Carestream NDT. Kakivik Asset Management Serves Customers in Rugged Environments with Ease.
Frequently Asked Questions
What costs should be compared before moving away from film?
Beyond film costs, the assessment should include chemicals, processing, inventory, archiving, transportation, retakes, crew hours, and the time required to obtain an acceptable radiograph.
Is computed radiography still useful during the transition?
Yes. CR eliminates chemical processing and provides geometric flexibility, making it suitable for applications where a digital detector array cannot be positioned as easily.
When does direct digital radiography deliver the greatest value?
DR delivers greater value when immediate image availability reduces retakes, travel, or waiting time, provided the detector meets the technical requirements of the inspection application.
What role does industrial radiography software play?
It integrates image acquisition, analysis, traceability, and archiving. A common platform helps maintain workflow consistency when CR and DR operate within the same inspection program.